Home Forums SYSTEM BER analyzer problem in Coherent detection QPSK system

Viewing 4 reply threads
  • Author
    Posts
    • #41710
      Mahmudul Islam
      Participant

      I simulate the coherent detection QPSK system file from optisystem 13 samples but the min BER is 1 and Q factor is 0. Can anyone help me???

    • #41712
      Mahmudul Islam
      Participant

      Please any expert help me

    • #41889
      jagan padhy
      Participant

      Hallo everybody,I am also finding the same problem in BER analyser.eventhough eye diagram is comming but the values of q factor and ber rate is 0 and 1.so please help,anyone experts

    • #41895
      Damian Marek
      Participant

      You will notice that in our most recent project files we no longer use the BER Analyzer for Advanced Modulation formats. Constellation visualizers or BER Test Sets are used to calculate the BER.

      The reason being the BER Analyzer approximates the BER from analyzing the noise and eye characteristics. However, in the example you attach the electrical signal is being regenerated right before the BER Analyzer creating a signal with no noise or distortion in any way, even though the signal might actually be regenerated incorrectly.

    • #42551
      Priti Garg
      Participant

      hi Damian

      I read in one of the posts that there is a bug in BER test set, i am using it to find BER for an ofdm based system can u please clarify.