- This topic has 2 replies, 2 voices, and was last updated 6 years, 4 months ago by .
- You must be logged in to reply to this topic.
Optiwave software can be used in different industries and applications, including Fiber Optic Communication, Sensing, Pharma/Bio, Military & Satcom, Test & Measurement, Fundamental Research, Solar Panels, Components / Devices, etc..
OptiOmega is a collection of products specialized for photonic integrated circuit simulation. It automates the design flow for
generating compact models from device level simulations. The software package includes two solvers that can be used via
Python scripting: Vector Finite Difference (VFD) Mode Solver and Finite Difference Time Domain (FDTD) Electromagnetic Solvers.
Download our 30-day Free Evaluations, lab assignments, and other freeware here.Â
Optiwave software can be used in different industries and applications, including Fiber Optic Communication, Sensing, Pharma/Bio, Military & Satcom, Test & Measurement, Fundamental Research, Solar Panels, Components / Devices, etc..
OptiOmega is a collection of products specialized for photonic integrated circuit simulation. It automates the design flow for
generating compact models from device level simulations. The software package includes two solvers that can be used via
Python scripting: Vector Finite Difference (VFD) Mode Solver and Finite Difference Time Domain (FDTD) Electromagnetic Solvers.
Download our 30-day Free Evaluations, lab assignments, and other freeware here.Â
I want to calculate the BER. MY output of the cancelation diagram is correct but BER is 1. I also add a result digram. Can anyone guide me on how to solve this issue?
Dear Ali,
If the constellation diagram looks fine and the eye looks very clean as shown in the image you’ve attached, then there is an issue with setting up (connection) the BER test set.
It is too difficult to provide guidance without have access to your project. Will you be able to email it to me at ahmad.atieh@optiwave.com as a zip file, and I’ll try to help?
Regards,
Ahmad
Thanks for the reply. I attached the BER analyzer at the output of DSP. Two input with DSP output and one with parallel to serial after the Demodulation. I also send the snape Your email.