- This topic is empty.
-
AuthorPosts
-
-
March 19, 2018 at 11:55 am #48084Junhau KhooParticipant
Hello, May I ask a question? Recently, I got a project to analysis the effect of SBS and SRS by using Optisystem. But I dont know how to define the optical fiber that I used as Brillouin and Raman fiber. May I ask how to define the fiber?
-
March 21, 2018 at 2:22 pm #48179Mohamed A. A. AbouseifParticipant
Hi Junhau,
attached is two examples for SBS and SRS you can use them as a start point to go further with your projects.best of luck
Mohamed Abouseif -
March 23, 2018 at 10:48 am #48224Junhau KhooParticipant
Why I cannot open the file? Is it because I uses the old version of optisystem which is Optisystem 7?
-
March 23, 2018 at 11:26 am #48225Mohamed A. A. AbouseifParticipant
exactly,
try to download the evaluation version of optisystem15 for 1 month.best of luck
Mohamed Abouseif -
March 24, 2018 at 3:50 am #48229Junhau KhooParticipant
Ok. Thank you very much for helping.
And I have a one question. May I ask you?
Because now I use the design of Raman scattering separated channels inside the optiststem library. During the analysis, I added the Ideal Demultiplexer but the signal shown on the analyzer and meter for each channel is same. The signal shown is the output of the first channel in the input which is used as the pump signal.
What is the problem? Is it my setting wrong at the Demux part?
-
March 24, 2018 at 3:54 am #48230Junhau KhooParticipant
This is the file
-
March 26, 2018 at 8:38 am #48236Mohamed A. A. AbouseifParticipant
Hi Junhau,
I think it is expected to have the same readings from all output ports!
if you want to separate the channels I think you have to us filters either optical filter before the APD or electrical one.
In this case, you can see some differences of the output signals.
please do not forget to center the Filter on the wavelength for its corresponding channel.Hope this clear and helps.
Regards,
Mohamed Abouseif -
March 26, 2018 at 12:01 pm #48242Junhau KhooParticipant
Hi
Ohh…ok. I know what I should do. Thanks you very much.
Sir, I cannot open the simulation file even I use OptiSystem 15 already. That said about the violation. -
March 26, 2018 at 12:35 pm #48243Mohamed A. A. AbouseifParticipant
Great,
which file, that you can not open it?
-
April 1, 2018 at 11:22 am #48304Junhau KhooParticipant
For the Brillouin one~
-
April 3, 2018 at 7:57 am #48330Mohamed A. A. AbouseifParticipant
just you need to check the Brillouin scattering check_box and you might uncheck all other parameters,
you will see 11GHz back scattered signal which in Brillouin one.hope this helps
thanks
Mohamed -
April 3, 2018 at 8:48 pm #48346Junhau KhooParticipant
So is it means that I just check the Brillouin scattering in Enhancement and all check boxes for others like dispersion uncheck? Does this means?
-
April 4, 2018 at 7:37 am #48356Mohamed A. A. AbouseifParticipant
yes, try that pls.
thanks
Mohamed Abouseif -
April 6, 2018 at 11:04 pm #48390Junhau KhooParticipant
Ok, I try~thank you very much~
-
April 9, 2018 at 7:34 am #48408Mohamed A. A. AbouseifParticipant
welcome,
best of luck
Mohamed Abouseif -
April 13, 2018 at 1:54 am #48513Junhau KhooParticipant
Thank you^^
May I ask?
For the billouin scattering, i try to uncheck the others but the graph plotted is without any intersection. Instead without uncheck, the output transmitted power is not becoming constant at the SBS limit. Is it my design or setting got something wrong? -
April 13, 2018 at 1:58 am #48515Junhau KhooParticipant
Thank you very much^^
May I ask the brillouin scattering again?
I try the way that sir said. But the graph plotted is without any intersection between the output and backscattered power. Instead without uncheck, there got the intersection point, but the the trend for the output power is not becoming constant at SBS limit. And I try to change some parameters and refering to the article that Sir given and still cannot solve it. Is it my design or any setting is wrong? -
May 22, 2018 at 9:42 am #48830Abbas AkbarzadehParticipant
I’m new to Optisystem and I want to simulate SBS with the help of optisystem I found a related post in page:
Setting for Brillouin & Raman fiber (Optisystem)
but when I was opening the “SBS-SRS.zip” file in optiwave 15 can’t open the file and these error messages appeared
for the file “BidirectionalOF_Brillouin_ExDescriptionAndPerformanceEffec_7Feb2018_V1_MA_.osd” :
“Failed to load document from storage”for the “NLOF_Brillouin_ExDescriptionAndPerformanceEffec_7Feb2018_V1_MA_.osd”
“A name clash occurred between a system parameter and user parameter in subsystem ’cw laser’ the user parameter was renamed to ’param1’ in only your scripts you must manually rename to param1”how can I solve this problem ?
-
-
AuthorPosts
- You must be logged in to reply to this topic.